QUESTION: I am having issues on MT polishing. I am getting “Y” radius less than 100. Can you advise which step should I reduce time or pressure?
ANSWER:
Customer had a need to increase y-axis radius on MT’s (making the surface “flatter”), was having difficulty. After trying the most common recommendations (reducing pressure, trying non-PSA films instead of PSA films) with no improvement, FOC technical team discussed as a group, and one recommendation to come from the meeting was to ensure proper torque was applied when fixing the ferrules to the fixture.
After providing this information to the customer, he used a new, calibrated torque wrench to fix the ferrules, and results were significantly improved—-customer yields are now at acceptable levels, he is happy.
ADDITIONAL CONTENT & RESOURCES:
- Category Resource: FOC Polish Page
- Find More Information in this Blog: Polishing Tips and Best Practices for Single Fiber Connectors

Have a technical question for Fiber Optic Center?
Please email your question to AskFOC@focenter.com and we will respond ASAP.
In addition to replying, we will post your question and our answer here on focenter.com. Everyone remains anonymous when we post so feel comfortable asking. You can also search your question and others in our content search.
This article is an original publication of Fiber Optic Center, Inc. It is shared publicly for educational and reference purposes to support learning and professional development within the fiber optics industry.
You are welcome to read, cite, or reference this material for non-commercial and educational purposes, as long as full credit is given to Fiber Optic Center, Inc. and the author.
Reuse, reproduction, or adaptation of this content — including rewriting, republishing, or incorporating it into new materials (such as websites, blogs, marketing text, technical guides, or AI-generated content) — is not permitted without prior written consent from Fiber Optic Center, Inc.
This material is protected by copyright law upon publication, even if not formally registered.
Use of this content for AI training, automated data extraction, or derivative content generation is prohibited.
Fiber Optic Center monitors and enforces the integrity of its intellectual property through digital identifiers and content tracking.
For more details, please refer to the Fiber Optic Center Content Use and Copyright policy.