QUESTION:
Is there a solution for getting LC/PC for return loss more than 60 dB? If it depends on final polishing film, is Ultimas final polishing film suitable? What kind of films will work? Is there a special polishing method?
ANSWER:
Unfortunately, there isn’t a special final film that produces 60 dB on UPC connectors. Our film is the most likely to get you there, but many other factors need to be considered including test leads on the RL meter. However, I dare say getting 60 dB with a decent yield, may not be doable without considerable scrap. Also, ultra-low return loss degrades with multiple mates, so you need to get it under the first test. Consider that you may test -60.5 dB on the first test with ‘fresh’ test leads, but if the customer tests the next time with the best test leads, it may be -59 dB, then -57 dB, then finally settle somewhere below that.
Here are a few additional comments:
-
In terms of polishing process, there’s not much more that can be done with current state of lapping films.
-
To tweak out the last few dB’s, you need to focus on core alignment (highest concentricity ferrules and fibers, and most precise adapter split-sleeves) that can be found.
-
RL values are not a characteristic of the connector itself, but of the mated pair. A RL limit of 60 dB in production will mean you’ll need to constantly replacing test leads. The end user will likely not be able to correlate results.
-
If end user truly needs 60’s, APC’s are the way to go.
ADDITIONAL CONTENT & RESOURCES:
- Category Resource: FOC Film Page
- Find More Information in this Blog: Polishing Tips and Best Practices for Single Fiber Connectors
- Find More Information in this Blog: Why Do Scratches Appear After Using the Final Film?

Have a technical question for Fiber Optic Center?
Please email your question to AskFOC@focenter.com and we will respond ASAP.
In addition to replying, we will post your question and our answer here on focenter.com. Everyone remains anonymous when we post so feel comfortable asking. You can also search your question and others in our content search.
This article is an original publication of Fiber Optic Center, Inc. It is shared publicly for educational and reference purposes to support learning and professional development within the fiber optics industry.
You are welcome to read, cite, or reference this material for non-commercial and educational purposes, as long as full credit is given to Fiber Optic Center, Inc. and the author.
Reuse, reproduction, or adaptation of this content — including rewriting, republishing, or incorporating it into new materials (such as websites, blogs, marketing text, technical guides, or AI-generated content) — is not permitted without prior written consent from Fiber Optic Center, Inc.
This material is protected by copyright law upon publication, even if not formally registered.
Use of this content for AI training, automated data extraction, or derivative content generation is prohibited.
Fiber Optic Center monitors and enforces the integrity of its intellectual property through digital identifiers and content tracking.
For more details, please refer to the Fiber Optic Center Content Use and Copyright policy.